ACE6291 Real Time Signal Analyzer
Tab Description
Uses & Features

Features

- Pocket Real-Time Noise Signal Analyzer

- Real-time 1/1 and 1/3 Octave Band Analysis is available

- FFT analysis on noise or vibration

- Lower background noise

- 90 dB (ACE6291) or 100 dB (ACE6228) Level Linearity Range

- Different software could be selected

- Auto-start and auto-end

 

Uses

- Precision acoustics measurements

- Real-time frequency analysis in 1/1 and 1/3 octave digital filters

- Environmental noise measurement and 24 hour monitoring

- Reverberation time measurements

- Airport Noise Monitoring and data collect

 

 

Technical Specification
Items ACE6291
 Fulfils Standards  IEC 61672 Class 1 and IEC 61260 Class 1
 Microphone  1/2" Prepolarized Condenser Mic.
 Model AWA14423 (sensitivity : 50 mV/Pa)
 Preamplifier      AWA14601
 Frequency Range 10 Hz  10 Hz ~ 16 kHz
 Range Gain

 -10 dB, 0 dB, 10 dB, 20 dB, 30 dB, 40 dB

 Range Error: ≤ 0.1 dB

 Self-Generated Noise  <18 dB (A), 23 dB (C), 28 dB (Z)
 Meas. Upper Range  140 dB
 Peak C Sound Level Measuring Range  50 dB ~ 143 dB
 Frequency Weighting  Parallel (Simultaneous) A, C, Z. Realized by Digital Filtering
 Time Weighting  Parallel (Simultaneous) F, S, I, Peak
 A/D Bits  24 bits
 Level Linearity Range  > 100 dB
 Sampling Frequency  > 90 dB
 Display  240 x 160 graphic LCD, with EL back-lit
 Display Refresh  1 Hz for value; 10 Hz for graph
 Main Parameters of Integrating Measurement

 Lxyp, Lxyi, Lxeq,1s, Lxeq,T, LAE, E, Cpeak, LAFmax, LAFmin, LAFeqT, LASeqT, LAIeqT. 

  Note: X is A, C, Z and Y is F, S, I.

 Main Parameters of Airport Noise Measurement  LEPN,Td,Lmax
 Display Resolution  0.1.dB
 Real-time Analysis Speed  Approx. 47 times / s (It can simultaneously complete all center frequencies and A, C, Z weighting.).
 Statistical Analysis Function

 Statistical Analysis Software (S6228-00101)

 The statistical analysis menu : LAFp, LAFmax,LAF5, LAF10, LAF50, LAF90, LAF95, LAFmin, SD, LAeq1 s, LAeq, T, LAE, LAFeqT. 24h measures menu: And Ld, Ln, Ldn.

 Real-Time Spectrum Analysis 

 Fulfils Standards : IEC 61260 Class 1

 Filter Type : Digital band-pass filter

 Measuring Parameters : Lfmi, Lfmeq,1s, Lfmeq,T, Lxyp, Lxyi, Lxeq,1s, Lxeq,T, LAE, E, Cpeak, Tm.

 Note: fm is center frequency; X is frequency weighting A, C, Z. Y is time weighting F, S, I

 Real-Time 1/1 OCT Spectrum Analysis  1/1 OCT Spectrum Analysis Software (S6228-00202)
 Filters Center Frequency : 16 Hz ~ 16 kHz
 Real-Time 1/3 OCT Spectrum Analysis  1/3 OCT Spectrum Analysis Software (S6228-00303)
 Filters Center Frequency : 10 Hz ~ 20 kHz
 Real-Time 1/3 OCT Spectrum Analysis

 FFT analysis software for noise (S6291 -00404)

 1) Line Number : 200 lines on the display.

 2) Sampling Frequency : 48 kHz, 24 kHz, 12 kHz, 6 kHz, 3 kHz, 1.5 kHz.

 3) Upper Limit of Analysis Frequency: 18.75 kHz, 9375 Hz, 4687 Hz, 2344 Hz, 1172 Hz, 586 Hz.

 4) Bandwidth of each line : 93.75 Hz, 46.875 Hz, 23.438 Hz, 11.74 Hz, 5.8594Hz, 2.9297 Hz

 5) Average Method : index and linearity

 6) Measuring Parameters : Lxyp, Lxyi, Lxeq,1s, Lxeq,T, LAE, E, Cpeak, Tm in every line

Reverberation Time Measurement Function (Optional)

 Reverberation Time Measurement Software (S6291 - 00508)
 1) Function : Reverberation time, EDT measurement by integrated impulse response method

 2) Fulfils Standard : ISO 3382

 3) Measuring Parameters : T20, T30, EDT

 4) Measuring Range : 0.20 s to 20.00 s

 5) Wave Record Time : 10 s or 20 s

 6) Bandwidth of digital filters : 1/1 OCT or 1/3 OCT

 7) Center Frequency Ranges : 63 Hz ~ 16 kHz for Oct., 40 Hz ~ 16 kHz for 1/3 Oct

 8) Date store : Max 12288 groups reverberation time, also translate to U disc

 Data Storage

 64M bits Flash, instantaneous data, 1 second integral results and integral measuring result (maximum 12288 groups).

 Also can be stored in Flash disk or transferred to the Flash disk through USB interface

 Integral Time  Manual, 10 s, 1 min, 5 min, 10 min, 15 min, 20 min, 30 min, 1h, 4h, 8h, 24h or 1 min ~ 59 min
 Print  Can print analytical results in the mini-print, can also print the contents showed on LCD screen
 Data Recall  Recalled any data
 Intelligent Delete  Burst event may be deleted scientifically
 Internal Clock  Error less than 1 min / month
 Output Interface

 Stereo Connector AC Signal Output                                                                                                                                                 RS 232 interface to the mini-printer, or connected to PC
 USB Interface, which can transfer the measuring results to PC, or the Flash disk.

 Power Supply  6 x LR6 alkaline battery or rechargeable batteries, which can work for over 12 hours continuously.                                              9V external power supply is also acceptable.
 Dimensions  310(H) × 90(W) × 38(D) mm
 Weight      0.5 kg (include batteries)
 Electromagnetic Compatibility  Type X
 Working Temperature  -10 0C ~ 50 0C
 Storing Temperature  -20 0C ~ 70 0C
 Relative Humidity  25% ~ 90 %
 Atmospheric Pressure  65 kPa ~ 108 kPa

ACE6291 Real Time Signal Analyzer

Sound Level Meter

Features

- Pocket Real-Time Noise Signal Analyzer

- Real-time 1/1 and 1/3 Octave Band Analysis is available

- FFT analysis on noise or vibration

- Lower background noise

- 90 dB (ACE6291) or 100 dB (ACE6228) Level Linearity Range

- Different software could be selected

- Auto-start and auto-end

 

Uses

- Precision acoustics measurements

- Real-time frequency analysis in 1/1 and 1/3 octave digital filters

- Environmental noise measurement and 24 hour monitoring

- Reverberation time measurements

- Airport Noise Monitoring and data collect

 

 

Items ACE6291
 Fulfils Standards  IEC 61672 Class 1 and IEC 61260 Class 1
 Microphone  1/2" Prepolarized Condenser Mic.
 Model AWA14423 (sensitivity : 50 mV/Pa)
 Preamplifier      AWA14601
 Frequency Range 10 Hz  10 Hz ~ 16 kHz
 Range Gain

 -10 dB, 0 dB, 10 dB, 20 dB, 30 dB, 40 dB

 Range Error: ≤ 0.1 dB

 Self-Generated Noise  <18 dB (A), 23 dB (C), 28 dB (Z)
 Meas. Upper Range  140 dB
 Peak C Sound Level Measuring Range  50 dB ~ 143 dB
 Frequency Weighting  Parallel (Simultaneous) A, C, Z. Realized by Digital Filtering
 Time Weighting  Parallel (Simultaneous) F, S, I, Peak
 A/D Bits  24 bits
 Level Linearity Range  > 100 dB
 Sampling Frequency  > 90 dB
 Display  240 x 160 graphic LCD, with EL back-lit
 Display Refresh  1 Hz for value; 10 Hz for graph
 Main Parameters of Integrating Measurement

 Lxyp, Lxyi, Lxeq,1s, Lxeq,T, LAE, E, Cpeak, LAFmax, LAFmin, LAFeqT, LASeqT, LAIeqT. 

  Note: X is A, C, Z and Y is F, S, I.

 Main Parameters of Airport Noise Measurement  LEPN,Td,Lmax
 Display Resolution  0.1.dB
 Real-time Analysis Speed  Approx. 47 times / s (It can simultaneously complete all center frequencies and A, C, Z weighting.).
 Statistical Analysis Function

 Statistical Analysis Software (S6228-00101)

 The statistical analysis menu : LAFp, LAFmax,LAF5, LAF10, LAF50, LAF90, LAF95, LAFmin, SD, LAeq1 s, LAeq, T, LAE, LAFeqT. 24h measures menu: And Ld, Ln, Ldn.

 Real-Time Spectrum Analysis 

 Fulfils Standards : IEC 61260 Class 1

 Filter Type : Digital band-pass filter

 Measuring Parameters : Lfmi, Lfmeq,1s, Lfmeq,T, Lxyp, Lxyi, Lxeq,1s, Lxeq,T, LAE, E, Cpeak, Tm.

 Note: fm is center frequency; X is frequency weighting A, C, Z. Y is time weighting F, S, I

 Real-Time 1/1 OCT Spectrum Analysis  1/1 OCT Spectrum Analysis Software (S6228-00202)
 Filters Center Frequency : 16 Hz ~ 16 kHz
 Real-Time 1/3 OCT Spectrum Analysis  1/3 OCT Spectrum Analysis Software (S6228-00303)
 Filters Center Frequency : 10 Hz ~ 20 kHz
 Real-Time 1/3 OCT Spectrum Analysis

 FFT analysis software for noise (S6291 -00404)

 1) Line Number : 200 lines on the display.

 2) Sampling Frequency : 48 kHz, 24 kHz, 12 kHz, 6 kHz, 3 kHz, 1.5 kHz.

 3) Upper Limit of Analysis Frequency: 18.75 kHz, 9375 Hz, 4687 Hz, 2344 Hz, 1172 Hz, 586 Hz.

 4) Bandwidth of each line : 93.75 Hz, 46.875 Hz, 23.438 Hz, 11.74 Hz, 5.8594Hz, 2.9297 Hz

 5) Average Method : index and linearity

 6) Measuring Parameters : Lxyp, Lxyi, Lxeq,1s, Lxeq,T, LAE, E, Cpeak, Tm in every line

Reverberation Time Measurement Function (Optional)

 Reverberation Time Measurement Software (S6291 - 00508)
 1) Function : Reverberation time, EDT measurement by integrated impulse response method

 2) Fulfils Standard : ISO 3382

 3) Measuring Parameters : T20, T30, EDT

 4) Measuring Range : 0.20 s to 20.00 s

 5) Wave Record Time : 10 s or 20 s

 6) Bandwidth of digital filters : 1/1 OCT or 1/3 OCT

 7) Center Frequency Ranges : 63 Hz ~ 16 kHz for Oct., 40 Hz ~ 16 kHz for 1/3 Oct

 8) Date store : Max 12288 groups reverberation time, also translate to U disc

 Data Storage

 64M bits Flash, instantaneous data, 1 second integral results and integral measuring result (maximum 12288 groups).

 Also can be stored in Flash disk or transferred to the Flash disk through USB interface

 Integral Time  Manual, 10 s, 1 min, 5 min, 10 min, 15 min, 20 min, 30 min, 1h, 4h, 8h, 24h or 1 min ~ 59 min
 Print  Can print analytical results in the mini-print, can also print the contents showed on LCD screen
 Data Recall  Recalled any data
 Intelligent Delete  Burst event may be deleted scientifically
 Internal Clock  Error less than 1 min / month
 Output Interface

 Stereo Connector AC Signal Output                                                                                                                                                 RS 232 interface to the mini-printer, or connected to PC
 USB Interface, which can transfer the measuring results to PC, or the Flash disk.

 Power Supply  6 x LR6 alkaline battery or rechargeable batteries, which can work for over 12 hours continuously.                                              9V external power supply is also acceptable.
 Dimensions  310(H) × 90(W) × 38(D) mm
 Weight      0.5 kg (include batteries)
 Electromagnetic Compatibility  Type X
 Working Temperature  -10 0C ~ 50 0C
 Storing Temperature  -20 0C ~ 70 0C
 Relative Humidity  25% ~ 90 %
 Atmospheric Pressure  65 kPa ~ 108 kPa



Copyright 2026 by Emetrology Pte Ltd. All Rights Reserved.